Alcadex® A2 meets the higher requirements of fire regulations in architecture. With more and more fire accidents coming from high rise building,the governments also upgrade the fire code to avoid life and property big lost. Alcadex® A2 offers architecture more solution after meeting fire...
  • Alcadex® A2 meets the higher requirements of fire regulations in architecture. With more and more fire accidents coming from high rise building,the governments also upgrade the fire code to avoid life and property big lost. Alcadex® A2 offers architecture more solution after meeting fire performance requirements by markets.

    Structure

    Protective film to protect panel surface 

    PVDF coating with clean or colors applied on aluminium sheet.

    Polymeric membrane composites the aluminiumonto core.

    A2 mineral core

    Specification

    Width

    1000mm / 1220mm / 1250mm / 1500mm / 1575mm

    Panel Thickness

    3mm, 4mm & 5mm

    Aluminium Alloy

     AA3003 / AA5005

    Aluminium Thickness

    0.15mm-0.70mm

    Coating

    PE / PVDF / Nano / FEVE

    Fireproof Core

    Non-combustible core

    Length

    4000mm in maximum

    Color

    Solid / Metallic / Marble / Wooden / Brush / Glossy /Mirror

    MOQ

    800 SQM/size/color

    Brand / OEM

    ALCADEX® / Customized

    Delivery

    20 day after getting deposit and color confirmation

    Payment Terms

    T/T / L/C / Western Union / Paypal

    Packing

     Pallet or bulk loading


     Fireproof  Classification

    Country

    Test Standard

    Result & Classification

    Europe

    EN13501-2:2007+A1:2009

    EL 120    minutes

    EN-13501-01

    A2, s1    d0

    United    States

    ASTM    E84

    FSI    0,SD0

    NFPA285

    Pass

    United    Kingdom

    BS476    Part 6
         Part 7

    Index 0
         Class 1

    Australia

    AS1530.3

    Pass

    Fire Rating Comparison

     

    Alcadex®ACM
         (Traditional ACM)

    Alcadex®FR
         (Fireproof panel)

    Alcadex® A2
         (A2 fireproof)

    Fire Standard

    Group Number

    Group 3

    Group 2

    Group 3

    EN13501-1-2007

    Fire Behavior

    D

    B

    A2

    Smoke Production

    s

    s1

    s1

    Burning Droplets

    d2

    d0

    d0

    Classification

    d-s2

    B-s1-d0

    A2-s1-d0

    Welcome to buy the nfpa 285 a2 fire-retardant aluminium composite panel building materials from our factory. As one of the professional manufacturers and suppliers in China, we will offer you good price and excellent service.


  • Panel Installation Notice

    Do not stick PVC tapes, polyurethane and modified silicon sealant onto protective film.

    Plasticizers contained in these materials penetrate the film and may cause glossy changeon the coating

    Please peel off the protective film within 45 days after installation

    All the panels installation should follow protective film arrow and keep all arrows same direction. Otherwise may cause color aberration after protective film peeling off.

    Correct Installation direction:

    Wrong Installation direction:

    Cleaning and Maintanence

    It is highly recommended that when using any type of cleaner, personal safety and protection is the top priority. Please use appropriate skin and eye protection to prevent chemical irritation or burns before commencement of works.

    The amount of dirt accumulation on Alcadex® panels depends on a numbers of factors, but more importantly upon the building’s geographic location and position. Other varying factors that should be considered when scheduling the cleaning of the panels are panel location on the building structure, local soil type, weather, amount of dirt build up and pollution.

    Always test cleaning materials, cleaners and procedures on a small inconspicuous area prior to use on a large scale.

    Normal dust and dirt: a 5% solution (one part detergent to 20 parts of water) of commonly used industrial detergents will not have any deleterious effect on the PVDF coated surface.

    For rust stains or dried mortar / concrete: hydrochloric acid (10% muriatic acid) diluted with ten parts water would be effective in such cases. It is very important that a small area be tested to see if this will affect the panel surface before proceeding with cleaning the entire project. 